RS232 CONFIG
Register Address Register Name Function Read/Write Control
0x16
RS232CONFIG
RS232 baud rate and
flow control
configuration
Read/Write
Register Size Register structure Unit
1 Byte Unsigned Int 8 bits none
Description:
RS232 baud rate and flow control configuration.
Bits 0-2 Baud rate configuration :
0 : 4800 bds
1 : 9600 bps (default)
2 : 19200 bps
3 : 38400 bps
4 : 57600 bps
5 : 115200 bps
6 : 115200 bps
7 : 115200 bps
Bits 3-6 Reserved
Bit 7 Hardware flow control bit (0 = disabled, 1 = enabled)
Default value:
1 (9600 bps without flow control)