RESTORE FACTORY PARAMETERS
Function
Address
Function Name
Function Read/Write Control
0x05
RESTOREFACTORYPARAMETERS
Factory default Write only
Register Size Register structure Unit
0 Byte none none
Description:
Restores the following parameters from factory EEPROM space:
0x12 IPADDRESS
0x13 SUBNETMASK
0x14 TCPTIMEOUT
0x15 MODULENAME
0x16 RS232CONFIG
Note:
SAVEUSERPARAMETERS should be performed after this function in order to
save restored parameters as user parameters.